PRODETECH DATCP

DATCP 4 - protects and controls up to 4 devicesDigital Automatic Transfer Control Panel [DATCP] is a special device designed to protect up to 4 ACU motors including dual – Air Conditioning Systems.

Its special design enables the AC Unit motor to function continuously and alternately at a specific preset period of time using the Programmable Digital Timer. This will automatically transfer the workload to the other AC Unit motor if malfunction occur in one AC unit motor. In the event of extreme and rapid two lines power fluctuation or a sudden voltage interruption, this special device has a built in solid state circuit sensor that monitors the power supply until the power stabilizes and enable the AC units to return to their normal operation. It also has a temperature sensor that enables the users to set the desired temperature inside the room. This device saves up to 30% on electric bills.

Truly "protection beyond expectation!"

  • DATCP is available in a variety of models; Single Phase, Three Phase and Contactor Type models to suit your requirements.
  • DATCP has models for 2 and 4 device set-up/systems.
  • All DATCP Electronic Motor Protectors carry a 1 year parts and service warranty, except tampered units.

General Specifications:

  • Available Models1-Phase, 3-Phase, Contactor Type
  • Power Rating 1/4 to 500 HP
  • Operating Voltage100 Vac, 220 Vac, 440 Vac, 480 Vac
  • Power-On Delay 3 to 5 minutes
  • Over Voltage Cut-off260 Vac
  • Under Voltage Cut-off180 Vac
  • ACU Maximum Load5HP for Plug-in Model
  • Transfer Switching1 to 12 Hrs Program
  • Temperature Switching20 to 28 Degrees Centigrade
  • Ambient Temperature0 to 60 Degrees Centigrade
  • Dimensions (L x H x D)310mm x 330mm x 150mm
  • Weight 10 Kilograms / 22 Pounds

APPLICATIONS

Prodetech DATCP is primarily designed for unmanned telecommunication repeater and cell sites specially in remote areas with 2 or more air conditioning units. This device will enable the AC units to function continuously through setting the programmable timer from 2 to 12 hours time duration for each unit.
The use of this device is highly recommended for telecommunications sites, office buildings, production studios, auditoriums, data centers, laboratories, hotels, schools, universities, electronic billboards, shopping malls and other commercial establishments. It guarantees longer life span for your aircon units /electric motors with a well maintained voltage and temperature all the time.

PRODETECH DCTS
 Digitally Controlled Transfer Switch with Electronic Motor Protector

Electronic Motor Protector - Protection and Monitoring System
Composed of four sets of innovative electronic circuit boards for more efficient motor protection against damaging effect of power supply fluctuations.

DCTS -2 device set-up / systems

  • Auto-disconnect, Auto-reconnect
  • 15ns Respond Time
  • Safe/Normal Power Indicator
  • Standby/Power-On Delay Indicator
    3 to 5 minute delay transition from a power fluctuation to safe/normal operation.
  • Under Voltage Indicator
    When low line voltage is present on the power supply, the sensors will automatically disconnect the power of the functioning aircon unit or device. As soon as the power stabilizes, normal operation will resume after 3 to 5 minute delay. Cut-off voltage is 180 Vac.
  • Over Voltage Indicator
    When high line voltage is present on the power supply, the sensors will automatically disconnect the power of the functioning aircon unit or device. As soon as the power stabilizes, normal operation will resume after 3 to 5 minute delay. Cut-off voltage is 260 Vac.
  • Overload Indicator
  • Overload Reset Switch
  • Single Phasing monitor for Three Phase

DCTS Programmable Digital Timer

  • 24- Hr or 7-day timer
  • 16-memory space
  • Holiday program
  • Easy to use prompt programming
  • SPDT heavy duty relay with dry contact
  • Built-in Lithium back up battery
  • AM/PM LCD display with backlight
  • Clear Snap-On Plastic Duct cover
  • Wide Power Supply Voltage Range
  • Automatic or Manual Operation
  • UL, CE approved

Digital Temperature  Controller

  • 7-Segment Digital LED Display
  • Programmable Temperature Controller
  • New Processing System
  • Multi Input, Muti-range Performance
  • Improved PID Control Efficiency
  • Built-in Lithium Back-up Battery
  • Keylock Function
  • High & Low Temperature Sensor
  • Standard K/J Type Thermocouple
  • Wide Power Supply Voltage Range

 

back to top

ACU Monitoring System
The lighted bright neon lamp determines which ACU/device monitoring system is functioning.

Standby/Power-On-Delay Indicators
When the standby / power-on-delay indicator lights, the motor protector is on a 3 to 5 minute delay transition from a power fluctuation or brown-out to safe/normal operation.

Under-Voltage Indicators
When low line voltage is present on the power supply, the sensors automatically disconnects the power of the functioning ACU or device. As soon as the power stabilizes, normal operation will resume after a 3 to 5 minute delay. Cut-off voltage is 180 Vac.

Power / Overload Reset Button
Four red push buttons are used to reset / re-start the electronic board back to its normal operation after sensing any abnormality in the system.

Safe / Normal Power Indicator
When the safe / normal power green indicator lights, the motor/device and power supply is operating under normal conditions.

Over-Voltage Indicators
When high line voltage is present on the power supply, the sensors automatically disconnects the power of the functioning ACU or device. As soon as the power stabilizes, normal operation will resume after a 3 to 5 minute delay. Cut-off voltage is 260 Vac.

Overload Indicators
When overload indicator blinks, the electric motor is experiencing overload condition. The motor protector will automatically disconnect the power supply of the functioning electric motor. Routine maintenance is required to check the cause of the overload on the motor.

Emergency By-pass Switch
Used for manual switching of AC units by disabling the DCTS for planned maintenance or repair purposes.

Programmable Digital Timer
A 7-day digital clock/timer used for accurate and efficient real time transfer switching of aircon units or devices to their respective programmed hours.

*Alarm Input / Output Facilities (Optional)
An overload (output) and smoke (input) alarm extension connection can also be integrated to the DCTS as an additional alarm monitoring system for added safety and protection. The alarm can even be customized to send information remotely. This is best for unmanned, remotely situated equipment or cell sites. 

PRODETECH DCTS with Digital Temperature Control is designed to alternately operate Aircon units at certain preset period of time and transfer automatically the workload from one aircon unit to the other in the event of aircon malfunction. In cases of severe main two line supply fluctuations or a return from power blackout, DCTS has an internal watchdog circuitry that waits on the two main line supply to stabilize before energizing the aircon units (enhanced power-on delay). A built-in temperature control device senses the room temperature and activates both aircon units in case of persistent high temperature.